Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 270
Filtrar
1.
Diagnostics (Basel) ; 14(7)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38611592

RESUMO

Monitoring for thrombosis and hemolysis is crucial for patients under extracorporeal or mechanical circulatory support, but it can be costly. We investigated correlations between hemolysis index (HI) and plasma-free hemoglobin (PFH) levels on one hand, and between the HI and plasma lactate dehydrogenase (LDH) levels on the other, in critically ill patients with and without extracorporeal or mechanical circulatory support. Additionally, we calculated the cost reductions if monitoring through HI were to replace monitoring through PFH or plasma LDH. In a single-center study, HI was compared with PFH and plasma LDH levels in blood samples taken for routine purposes in critically ill patients with and without extracorporeal or mechanical circulatory support. A cost analysis, restricted to direct costs associated with each measurement, was made for an average 10-bed ICU. This study included 147 patients: 56 patients with extracorporeal or mechanical circulatory support (450 measurements) and 91 patients without extracorporeal or mechanical circulatory support (562 measurements). The HI correlated well with PFH levels (r = 0.96; p < 0.01) and poorly with plasma LDH levels (r = 0.07; p < 0.01) in patients with extracorporeal or mechanical circulatory support. Similarly, HI correlated well with PFH levels (r = 0.97; p < 0.01) and poorly with plasma LDH levels (r = -0.04; p = 0.39) in patients without extracorporeal or mechanical circulatory support. ROC analyses demonstrated a strong performance of HI, with the curve indicating excellent discrimination in the whole cohort (area under the ROC of 0.969) as well as in patients under ECMO or mechanical circulatory support (area under the ROC of 0.988). Although the negative predictive value of HI for predicting PFH levels > 10 mg/dL was high, its positive predictive value was found to be poor at various cutoffs. A simple cost analysis showed substantial cost reduction if HI were to replace PFH or plasma LDH for hemolysis monitoring. In conclusion, in this cohort of critically ill patients with and without extracorporeal or mechanical circulatory support, HI correlated well with PFH levels, but poorly with plasma LDH levels. Given the high correlation and substantial cost reductions, a strategy utilizing HI may be preferable for monitoring for hemolysis compared to monitoring strategies based on PFH or plasma LDH. The PPV of HI, however, is unacceptably low to be used as a diagnostic test.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38514397

RESUMO

Latest research has indicated a potential adverse effect on graft patency rates and clinical outcomes with skeletonizing the left internal thoracic artery. We aim to provide a prospective, randomized, multicentre trial to compare skeletonized versus pedicled harvesting technique of left internal thoracic artery concerning graft patency rates and patient survival. A total of 1350 patients will be randomized to either skeletonized or pedicled harvesting technique and undergo surgical revascularization. Follow-up will be performed at 30 days, 1 year, 2 years and 5 years after surgery. The primary outcome will be death or left internal thoracic artery graft occlusion in coronary computed tomography angiography or invasive angiography within 2 years (+/- 3 months) after surgery. The secondary outcome will be major adverse cardiac events (composite outcome of all-cause death, myocardial infarction and repeated revascularization) within 1 year, 2 years and 5 years after surgery. The primary end point will be compared in the modified intention-to-treat population between the two treatment groups using Kaplan-Meier graphs, together with log-rank testing. Hereby, we present the study protocol of the first adequately powered prospective, randomized, multicentre trial which compares skeletonized and pedicled harvesting technique of left internal thoracic artery regarding graft patency rates and patient survival.

3.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38532286

RESUMO

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced in 2008 as a further option for paediatric aortic valve replacement (AVR). METHODS: Prospective, multicentre follow-up of all paediatric patients receiving DAH for AVR in 8 European centres. RESULTS: A total of 143 DAH were implanted between February 2008 and February 2023 in 137 children (106 male, 74%) with a median age of 10.8 years (interquartile range 6.6-14.6). Eighty-four (59%) had undergone previous cardiac operations and 24 (17%) had undergone previous AVR. The median implanted DAH diameter was 21 mm (interquartile range 19-23). The median operation duration was 348 min (227-439) with a median cardiopulmonary bypass time of 212 min (171-257) and a median cross-clamp time of 135 min (113-164). After a median follow-up of 5.3 years (3.3-7.2, max. 15.2 years), the primary efficacy end-points peak gradient (median 14 mmHg, 9-28) and regurgitation (median 0.5, interquartile range 0-1, grade 0-3) showed good results but an increase over time. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 5 years were 97.8 ± 1.2/88.7 ± 3.3/99.1 ± 0.9/100 and 99.2 ± 0.8%, respectively. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 10 years were 96.3 ± 1.9/67.1 ± 8.0/93.6 ± 3.9/98.6 ± 1.4 and 86.9 ± 11.6%, respectively. In total, 21 DAH were explanted. Seven were replaced by a mechanical AVR, 1 Ross operation was performed and a re-do DAH was implanted in 13 patients with no redo mortality. The calculated expected adverse events were lower for DAH compared to cryopreserved homograft patients (mean age 8.4 years), and in the same range as for Ross patients (9.2 years) and mechanical AVR (13.0 years). CONCLUSIONS: This large-scale prospective analysis demonstrates excellent mid-term survival using DAH with adverse event rates comparable to paediatric Ross procedures.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Tromboembolia , Criança , Humanos , Masculino , Aloenxertos/cirurgia , Valva Aórtica/cirurgia , Endocardite/cirurgia , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Reoperação , Resultado do Tratamento , Feminino , Adolescente
4.
J Endovasc Ther ; : 15266028241235876, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528650

RESUMO

CLINICAL IMPACT: On needs-based ex vivo monitoring of implantable devices or tissues/organs in cardiovascular simulators provides new insights and paves new paths for device prototypes. The insights gained could not only support the needs of patients, but also inform engineers, scientists and clinicians about undiscovered aspects of diseases (during routine monitoring). We analyze seminal and current work and highlight a variety of opportunities for developing preclinical tools that would improve strategies for future implantable devices. Holistically, mock circulation loop studies can bridge the gap between in vivo and in vitro approaches, as well as clinical and laboratory settings, in a mutually beneficial manner.

5.
Eur Heart J ; 45(8): 613-625, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38036414

RESUMO

BACKGROUND AND AIMS: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. METHODS: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. RESULTS: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1-3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). CONCLUSIONS: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros
6.
IEEE Trans Biomed Eng ; 71(2): 446-455, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37603484

RESUMO

OBJECTIVE: Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH (ShuttlePump). METHODS: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. RESULTS: Pump characteristics cover the entire required operating range for a TAH, providing 2.5-9 L/min of flow rate against 50-160 mmHg arterial pressures at stroke frequencies of 1.5-5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of <2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100 L, and 95% of the pump's blood volume was exchanged after 1.42 s. CONCLUSION AND SIGNIFICANCE: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump.


Assuntos
Insuficiência Cardíaca , Coração Artificial , Coração Auxiliar , Humanos , Pressão Arterial , Fluxo Pulsátil
7.
J Heart Lung Transplant ; 43(2): 251-260, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37769887

RESUMO

PURPOSE: The HeartMate 3 (HM3) left ventricular assist device (LVAD) has demonstrated excellent clinical outcomes; however, pump speed optimization is challenging with the available HM3 monitoring. Therefore, this study reports on clinical HM3 parameters collected with a noninvasive HM3 monitoring system (HM3 Snoopy) during echocardiographic speed ramp tests and Valsalva maneuvers. METHODS: In this prospective, single-center study, the HM3 data communication between the controller and pump was recorded with a novel data acquisition system. Twelve pump parameters sampled every second (1 Hz) and clinical assessments (echocardiography, electrocardiogram (ECG), and blood pressure measurement) during speed ramp tests were analyzed using Pearson's correlation (r, median [IQR]). The cause for the occurrence of pulsatility index (PI)-events during ramp speed tests and valsalva maneuvers was investigated. RESULTS: In 24 patients (age: 58.9 ± 8.8 years, body mass index: 28.1 ± 5.1 kg/m2, female: 20.8%), 35 speed ramp tests were performed with speed changes in the range of ±1000 rpm from a baseline speed of 5443 ± 244 rpm. Eight HM3 pump parameters from estimated flow, motor current, and LVAD speed together with blood pressure showed positive collinearities (r = 0.9 [0.1]). Negative collinearities were observed for pump flow pulsatility, pulsatility index, rotor noise, and left ventricular diameters (r = -0.8 [0.1]), whereas rotor displacement and heartrate showed absence of collinearities (r = -0.1 [0.08]). CONCLUSIONS: In this study, the HM3 Snoopy was successfully used to acquire more parameters from the HM3 at a higher sampling rate. Analysis of HM3 per-second data provide additional clinical diagnostic information on heart-pump interactions and cause of PI-events.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Manobra de Valsalva , Ecocardiografia , Coração Auxiliar/efeitos adversos
8.
ASAIO J ; 70(2): 107-115, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37831817

RESUMO

Effective treatment of heart failure with preserved ejection fraction (HFpEF) remains an unmet medical need. Although left atrial decompression using mechanical circulatory support devices was previously suggested, the heterogeneous HFpEF population and the lack of tailored devices have prevented the translation into clinical practice. This study aimed to evaluate the feasibility of left atrial decompression in HFpEF patients with a HeartMate 3 (HM3, Abbott Inc, Chicago, USA) in silico and in vitro . Anatomic compatibility of the HM3 pump was assessed by virtual device implantation into the left atrium through the left atrial appendage (LAA) and left atrial posterior wall (LAPW) of 10 HFpEF patients. Further, the efficacy of left atrial decompression was investigated experimentally in a hybrid mock loop, replicating the hemodynamics of an HFpEF phenotype at rest and exercise conditions. Virtual implantation without substantial intersection with surrounding tissues was accomplished through the LAA in 90% and 100% through the LAPW. Hemodynamic analysis in resting conditions demonstrated normalization of left atrial pressures without backflow at a pump speed of around 5400 rpm, whereas a range of 6400-7400 rpm was required during exercise. Therefore, left atrial decompression with the HM3 may be feasible in terms of anatomic compatibility and hemodynamic efficacy.


Assuntos
Apêndice Atrial , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Volume Sistólico , Átrios do Coração/cirurgia , Hemodinâmica , Descompressão , Função Ventricular Esquerda
9.
J Med Econ ; 27(1): 62-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38084737

RESUMO

BACKGROUND: VAD therapy has revolutionized the treatment of end-stage heart failure, but infections remain an important complication. The objective of this study was to characterize the clinical and economic impacts of VAD-specific infections. METHODS: A retrospective analysis of a United States claims database identified members ≥ 18 years with a claim for a VAD implant procedure, at least 6 months of pre-implant baseline data, and 12 months of follow-up between 1 June 2016 and 31 December 2019. Cumulative incidence of infection was calculated. Infection and non-infection cohorts were compared regarding mortality, healthcare utilization, and total cost. Regression models were used to identify risk factors associated with infections and mortality. RESULTS: A total of 2,259 patients with a VAD implant were included, with 369 experiencing infection (12-month cumulative incidence 16.1%). Patients with infection were 2.1 times more likely to die (p < 0.001, 95% CI [1.5-2.9]). The mean 12-month total cost per US patient was $354,339 for the non-infection cohort and $397,546 for the infection cohort, a difference of $43,207 (p < 0.0001). CONCLUSIONS: VAD infections were associated with higher mortality, more healthcare utilization, and higher total cost. Strategies to minimize VAD-specific infections could lead to improved clinical and economic outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estados Unidos/epidemiologia , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Revisão da Utilização de Seguros , Fatores de Risco , Resultado do Tratamento
10.
IEEE Trans Biomed Eng ; 71(5): 1651-1662, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133971

RESUMO

OBJECTIVE: Conventional mock circulatory loops (MCLs) cannot replicate realistic hemodynamic conditions without inducing blood trauma. This constrains in-vitro hemocompatibility examinations of blood pumps to static test loops that do not mimic clinical scenarios. This study aimed at developing an atraumatic MCL based on a hardware-in-the-loop concept (H-MCL) for realistic hemocompatibility assessment. METHODS: The H-MCL was designed for 450 ± 50 ml of blood with the polycarbonate reservoirs, the silicone/polyvinyl-chloride tubing, and the blood pump under investigation as the sole blood-contacting components. To account for inherent coupling effects a decoupling pressure control was derived by feedback linearization, whereas the level control was addressed by an optimization task to overcome periodic loss of controllability. The HeartMate 3 was showcased to evaluate the H-MCL's accuracy at typical hemodynamic conditions. To verify the atraumatic properties of the H-MCL, hemolysis (bovine blood, n = 6) was evaluated using the H-MCL in both inactive (static) and active (minor pulsatility) mode, and compared to results achieved in conventional loops. RESULTS: Typical hemodynamic scenarios were replicated with marginal coupling effects and root mean square error (RMSE) below 1.74 ± 1.37 mmHg while the fluid level remained within ±4% of its target value. The normalized indices of hemolysis (NIH) for the inactive H-MCL showed no significant differences to conventional loops ( ∆NIH = -1.6 mg/100 L). Further, no significant difference was evident between the active and inactive mode in the H-MCL ( ∆NIH = +0.3 mg/100 L). CONCLUSION AND SIGNIFICANCE: Collectively, these findings indicated the H-MCL's potential for in-vitro hemocompatibility assessment of blood pumps within realistic hemodynamic conditions, eliminating inherent setup-related risks for blood trauma.


Assuntos
Coração Auxiliar , Hemólise , Animais , Hemólise/fisiologia , Bovinos , Desenho de Equipamento , Hemodinâmica/fisiologia , Teste de Materiais/métodos , Modelos Cardiovasculares , Humanos
11.
ASAIO J ; 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081043

RESUMO

Driveline infection (DLI) is associated with increased mortality and morbidity in left ventricular assist device (LVAD) patients. Because trauma to the driveline exit-site (DLES) is a risk factor for DLI, adhesive anchoring devices are used to immobilize the DL. In this study, commonly used products (identified through literature review and contact with nine international VAD implantation centers) were mechanically characterized to evaluate their effectiveness in preventing DLES trauma. Eight devices were tested in an in vitro abdominal model of the DLES, where a tensile force (10 N) was applied to a HeartMate 3 DL, whereas the resulting force (FTotal) on the DLES was recorded using a three-axis load cell. Four devices (CathGrip: FTotal = 2.1 ± 0.4 N, Secutape: FTotal = 2.6 ± 0.3 N, Hollister: FTotal = 2.7 ± 0.5 N, Tubimed: FTotal = 2.9 ± 0.2 N) were significantly (p < 0.05) better at preventing tensile forces at the DLES compared to the other four devices (Main-Lock: FTotal = 3.7 [0.7] N, Secutape sensitive: FTotal = 3.9 ± 0.4 N, Foley Anchor: FTotal = 4.3 ± 0.5 N, Grip-Lok: FTotal = 5.4 ± 0.8 N). Immobilization of the DL with each anchoring device resulted in lower tensile force on the DLES than without an anchor (FTotal = 8.2 ± 0.3 N). In conclusion, the appropriate selection of anchoring devices plays a critical role in reducing the risk of DLI, whereas the CathGrip, Secutape, Hollister, or Tubimed were superior in preventing trauma to the DLES in this study.

13.
Artigo em Inglês | MEDLINE | ID: mdl-37942704

RESUMO

The Ross-Personalized External Aortic Root Support procedure is a surgical aortic valve replacement technique in which the autologous pulmonary valve is transposed in the aortic position to replace the malfunctioning aortic valve and a homograft is implanted in the pulmonary position. To prevent autograft dilatation, a Personalized External Aortic Root Support prosthesis is included in the proximal autograft anastomosis and wrapped around the ascending aorta. The aorta is transected transversely, the aortic valve is resected, and the coronary arteries are mobilized and cut out of the sinuses, leaving a rim. The pulmonary autograft is harvested by transecting the pulmonary artery and part of the right ventricular outflow tract. The autograft is approximated to the aortic root and inverted inside the ventricle. The proximal anastomosis is performed including the prosthesis between the aortic root and the autograft. The coronary buttons are threaded through appropriately positioned and sized holes in the prosthesis and reimplanted into the autograft. The ascending aorta is appropriately adapted and anastomosed with the distal autograft. When the patient is off cardiopulmonary bypass, the prosthesis can be closed longitudinally and is anchored to the distal aortic adventitia.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Humanos , Autoenxertos/cirurgia , Aorta Torácica/cirurgia , Transplante Autólogo , Valva Aórtica/cirurgia , Aorta/cirurgia , Estenose da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Pulmonar/transplante , Implante de Prótese de Valva Cardíaca/métodos , Reoperação
15.
JAMA ; 330(22): 2171-2181, 2023 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-37950897

RESUMO

IMPORTANCE: Left ventricular assist devices (LVADs) enhance quality and duration of life in advanced heart failure. The burden of nonsurgical bleeding events is a leading morbidity. Aspirin as an antiplatelet agent is mandated along with vitamin K antagonists (VKAs) with continuous-flow LVADs without conclusive evidence of efficacy and safety. OBJECTIVE: To determine whether excluding aspirin as part of the antithrombotic regimen with a fully magnetically levitated LVAD is safe and decreases bleeding. DESIGN, SETTING, and PARTICIPANTS: This international, randomized, double-blind, placebo-controlled study of aspirin (100 mg/d) vs placebo with VKA therapy in patients with advanced heart failure with an LVAD was conducted across 51 centers with expertise in treating patients with advanced heart failure across 9 countries. The randomized population included 628 patients with advanced heart failure implanted with a fully magnetically levitated LVAD (314 in the placebo group and 314 in the aspirin group), of whom 296 patients in the placebo group and 293 in the aspirin group were in the primary analysis population, which informed the primary end point analysis. The study enrolled patients from July 2020 to September 2022; median follow-up was 14 months. Intervention: Patients were randomized in a 1:1 ratio to receive aspirin (100 mg/d) or placebo in addition to an antithrombotic regimen. MAIN OUTCOMES AND MEASURES: The composite primary end point, assessed for noninferiority (-10% margin) of placebo, was survival free of a major nonsurgical (>14 days after implant) hemocompatibility-related adverse events (including stroke, pump thrombosis, major bleeding, or arterial peripheral thromboembolism) at 12 months. The principal secondary end point was nonsurgical bleeding events. RESULTS: Of the 589 analyzed patients, 77% were men; one-third were Black and 61% were White. More patients were alive and free of hemocompatibility events at 12 months in the placebo group (74%) vs those taking aspirin (68%). Noninferiority of placebo was demonstrated (absolute between-group difference, 6.0% improvement in event-free survival with placebo [lower 1-sided 97.5% CI, -1.6%]; P < .001). Aspirin avoidance was associated with reduced nonsurgical bleeding events (relative risk, 0.66 [95% confidence limit, 0.51-0.85]; P = .002) with no increase in stroke or other thromboembolic events, a finding consistent among diverse subgroups of patient characteristics. CONCLUSIONS AND RELEVANCE: In patients with advanced heart failure treated with a fully magnetically levitated LVAD, avoidance of aspirin as part of an antithrombotic regimen, which includes VKA, is not inferior to a regimen containing aspirin, does not increase thromboembolism risk, and is associated with a reduction in bleeding events. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04069156.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Tromboembolia , Masculino , Humanos , Feminino , Aspirina/efeitos adversos , Coração Auxiliar/efeitos adversos , Fibrinolíticos/efeitos adversos , Método Duplo-Cego , Insuficiência Cardíaca/fisiopatologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Inibidores da Agregação Plaquetária/efeitos adversos , Hemorragia/etiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
16.
Artigo em Inglês | MEDLINE | ID: mdl-38014822

RESUMO

We present the implant method and the postoperative management for an Impella 5.5 device via the right subclavian artery in a 72-year-old patient with severe left ventricular dysfunction upon weaning from cardiopulmonary bypass during a cardiac surgery procedure.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Disfunção Ventricular Esquerda , Humanos , Idoso , Disfunção Ventricular Esquerda/cirurgia , Artéria Subclávia , Ponte Cardiopulmonar , Resultado do Tratamento
17.
Cardiol Young ; 33(12): 2690-2692, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905342

RESUMO

In utero idiopathic constriction of the arterial duct is a rare condition with only a handful reported cases. Ductal aneurysms with thrombus formations on the other hand are significantly more common. We report a case of a term infant who presented with right heart failure due to premature ductal closure and postnatal severe respiratory distress. Subsequent diagnostics revealed paresis of left laryngeal nerve and obstruction of the left pulmonary artery secondary to a ductal aneurysm. Consequently, surgical intervention was considered necessary. Post-operatively, right ventricular function and hoarseness resolved slowly.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Insuficiência Cardíaca , Humanos , Canal Arterial/diagnóstico por imagem , Canal Arterial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Artéria Pulmonar
18.
Life (Basel) ; 13(10)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37895427

RESUMO

Mechanical circulatory support has proven effective in managing postcardiotomy cardiogenic shock by stabilizing patients' hemodynamics and ensuring adequate organ perfusion. Among the available device modalities, the combination of extracorporeal life support and a microaxial flow pump for left ventricular unloading has emerged as a valuable tool in the surgical armamentarium. In this publication, we provide recommendations for the application and weaning of temporary mechanical circulatory support in cardiogenic shock patients, derived from a consensus among leading cardiac centers in German-speaking countries.

19.
ASAIO J ; 69(11): 1016-1024, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37902686

RESUMO

Several device designs for cavopulmonary mechanical circulatory support (MCS) are under investigation, however, challenged by the Fontan population's heterogeneity in size, cardiovascular and thoracic anatomy. This study aimed to preclinically assess the anatomical compliance of proposed device designs in silico. Representative double- and single-outlet cavopulmonary assist device (CPAD) designs were virtually implanted into CT imaging data of 10 patients previously palliated with total cavopulmonary connection (TCPC) for functionally univentricular hearts. Anatomical device compatibility was characterized concerning pump proximity to cardiovascular, respiratory and thoracic structures, as well as pump in- and outflow graft configuration. In 10 Fontan patients with a median age of 10.4 years (interquartile range [IQR] 5.0-15.3 years) and a median body surface area of 1.09 m2 (IQR 0.76-1.28 m2), implantation of a double-outlet CPAD was feasible in 1 patient (10%). In all other, adverse device intersection with the trachea and (neo-)aorta, or posterior pulmonary artery outflow graft kinking were observed. A single-outlet design permitted enhanced device mobilization adapting to individual anatomical conditions, resulting in device fit in nine of 10 patients (90%). Despite vast anatomical variations among single ventricle patients, a single-outlet device design may provide intracorporeal cavopulmonary MCS to a broad spectrum of failing Fontan patients.


Assuntos
Aorta , Artéria Pulmonar , Humanos , Pré-Escolar , Criança , Adolescente , Superfície Corporal , Cooperação do Paciente , Pacientes
20.
J Am Coll Cardiol ; 82(21): 2034-2053, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37855757

RESUMO

As a result of increasing adoption of imaging screening, the number of adult patients with a diagnosis of anomalous aortic origin of the coronary arteries (AAOCA) has grown in recent years. Existing guidelines provide a framework for management and treatment, but patients with AAOCA present with a wide range of anomalies and symptoms that make general recommendations of limited applicability. In particular, a large spectrum of interventions can be used for treatment, and there is no consensus on the optimal approach to be used. In this paper, a multidisciplinary group of clinical and interventional cardiologists and cardiac surgeons performed a systematic review and critical evaluation of the available evidence on the interventional treatment of AAOCA in adult patients. Using a structured Delphi process, the group agreed on expert recommendations that are intended to complement existing clinical practice guidelines.


Assuntos
Anomalias dos Vasos Coronários , Vasos Coronários , Adulto , Humanos , Vasos Coronários/cirurgia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/terapia , Estudos Retrospectivos , Aorta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA